Healthcare MEP contractor for imaging and clinical rooms
Imaging equipment has MEP demands that a standard scope does not cover: dedicated earthing, EMI-aware cable routes, medical gases, and HVAC that holds tight temperature and humidity limits. We deliver them in step with the shielding, so every penetration is planned once.

Why MEP and shielding belong together
Healthcare MEP for imaging rooms is mechanical, electrical and plumbing work engineered around the equipment and its shield. The equipment sets dedicated requirements: earthing, power, cooling and humidity limits, medical gas outlets and cable routes that avoid electromagnetic interference. The shield sets the rule for everything that crosses it: in an MRI suite pipes pass through waveguides, ducts through honeycomb waveguide vents and electrical cables through RF filters, while in a lead-lined room each crossing needs a lead-backed sleeve or box. EGC plans every penetration on the drawings before anything is cut, in step with the shielding, then installs, pressure-tests and balances the services to the specified conditions and hands over as-built drawings and test records with the room. Doing both under one contractor means the details that normally fall between packages are drawn once instead of being found on site.
When shielding and MEP are separate packages, those crossings are discovered late and fixed on site. Under one contractor they are drawn once, before anything is cut.
Where it is used
- MRI suites
- CT and PET-CT rooms
- X-ray rooms
- Controlled clinical environments
What we deliver
- Medical gas pipeline systems: oxygen, medical air and vacuum
- Electrical infrastructure and earthing for imaging equipment
- EMI/RFI-aware cable routing and containment
- HVAC design and installation for controlled clinical environments
- Coordination with OEM installation teams during commissioning
- MEP shop drawings and as-built documentation
From our sites

Overhead services in a new building, with red sprinkler pipework above the ceiling line 
Painted steel hangers supporting services below the slab 
Electrical distribution panel with labelled, colour-coded wiring
What crosses the shield, and how
| Service | In an MRI suite | In a lead-lined room |
|---|---|---|
| Pipes (medical gases, water) | Pass through a waveguide in the RF shield | Pass through a lead-backed sleeve |
| Air ducts | Pass through a honeycomb waveguide vent in the RF shield | Cross through a lead-lined section or baffle |
| Power and data cables | Enter through RF filters, routed to the manufacturer’s requirements | Run in lead-backed boxes and containment |
| Quench pipe (MRI helium vent) | Routed to the outside to the manufacturer’s specification, and kept clear | Not applicable |
| Earthing | Dedicated earthing as the manufacturer specifies | Earthing to the equipment specification |
Who specifies what, and who builds it
| Who | What they do |
|---|---|
| Equipment manufacturer | States the heat load, power, cooling, humidity, gas and earthing the equipment needs. |
| Building services designer | Designs the building services and plant that serve the room. |
| Radiation protection physicist and equipment manufacturer | Define where and how services may cross the shield. |
| EGC | Plans every penetration with the shielding, installs, pressure-tests and balances the services, and hands over as-built drawings and test records. |
Building services we install
Medical Gas Systems
Oxygen, medical air and vacuum pipework, outlets, valves and alarms.
Healthcare HVAC
Temperature, humidity, pressure and filtration control for clinical spaces.
Fire Protection
Detection and alarm, sprinkler pipework and fire-stopping.
Nurse Call Installation
Cabling, call points, corridor lights and nurse-station units, tested bed by bed.
How we deliver it
Agree loads and routes
We take heat loads, power and service requirements from the OEM and agree routes with the design team.
Plan every penetration
Each crossing of the shielded envelope is located, detailed and sealed on the drawings first.
Install and test
Services are installed, pressure-tested and balanced to the specified conditions.
Document
As-built drawings and test records are handed over with the room.
Related disciplines
Radiation & magnetic shielding
Lead lining for CT, PET-CT and X-ray rooms; RF and magnetic shielding for MRI suites — built to the OEM and physicist specification.
Medical doors & access
Lead-lined and RF-shielded doors, hermetic sliding doors and access control — fabricated and fitted to seal controlled clinical areas.
Infection-control surfaces & joinery
Seamless, non-porous Corian solid surfaces and medical-grade joinery from our own factory, made for clinical cleaning protocols.
Planning an MRI, CT or PET-CT room?
Send us the equipment model and the site, and we will tell you what the room needs and how we would deliver it.